Home Introduction Products Honor Client Productivity Experiment Contact Us
 
 
 
Products
 
    PVC Insulated Power Cable insul  
     
 
PVC Insulated Power Cable insul
  • Type and designation

Type

Designation

VV

Copper conductor PVC insulated and sheathed power cable

VLV

Aluminum conductor PVC insulated and sheathed power cable

VY

Copper conductor PVC insulated PE sheathed power cable

VLY

Aluminum conductor PVC insulated PE sheathed power cable

VV22

Copper conductor PVC insulated steel tape armored PVC sheathed power cable

VLV22

Aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

VV23

Copper conductor PVC insulated steel tape armored PE sheathed power cable

VLV23

Aluminum conductor PVC insulated steel tape armored PE sheathed power cable

  • Description of the purpose and usage properties

The cable listed is applicable for power distribution and transmission line of rated voltage up to and including 3.6/6kV.

The maximum permitted long-term operating temperature of the cable shall be 70℃, with the maximum short-circuit (within 5 seconds) temperature being 160℃. The ambient temperature of installation of the cable shall not be less than 0℃.

The permitted bending radius of single core armored cable shall not be less than 20 times of the outer diameter of the cable, 15 times for multi-core armored cable, 15 times for single core non-armored cable, and 12 times for multi-core non-armored cable.

.Standard

GB 12706, IEC 60502, or Enterprise standard

  • Production scope

Type

Cores number

Rated voltage (kV)

0.6/1

1.8/3

3.6/6

Nominal cross-sectional area of conductor(mm²

VV、VY

1

1.5~1000

10~1000

10~1000

VLV、VLY

2.5~1000

10~1000

10~1000

VV22、VV23、VLV22、VLV23

10~1000

10~1000

10~1000

VV、VY

2、3

1.5~400

10~400

10~400

VLV、VLY

2.5~400

10~400

10~400

VV22、VV23、VLV22、VLV23

4~400

10~400

10~400

VV、VY

3+1、3+2、4、4+1、5

4~400

10~400

VLV、VLY

4~400

10~400

VV22、VV23、VLV22、VLV23

4~400

10~400

Note: The optional flame-retardant or fire-resistant types of the cables listed are also available.

For single core power cable, aluminum tape or non-magnetic material instead of steel tape should be utilized for armoring.

  • Delivery

The delivery length of the cable shall not be less than 100 meters. The short end not less than 20 meters shall be permitted in delivery, and the length of short ends shall not be more than 10% of the total length of each delivery.

Any delivery length shall be permitted in accordance with the mutual agreement of the purchaser and the manufacturer.

 
 
     
 
 
  Copy right ©:Qingdao Cable Co., Ltd.
ADD:No.16#,Jifalongshan Road,Environmental Protection Industry Park,Jimo,Qingdao,266201 China
 
 
 
Home Introduction Products Honor Client Productivity Experiment Contact Us